A correctly sized, correctly charged system attached to bad ductwork will still leave rooms uncomfortable. In older houses the duct is often the actual problem.

Financing is available on this work

Replacing or resizing a duct system is priced closer to a small construction job than to a repair, and it is financeable on the same terms as equipment. How financing works here.

Ask about financing

The core problem

Leaky attic duct is worse here than almost anywhere

Most houses in this part of Fort Bend County and southwest Houston run their supply and return ducts through the attic. On a summer afternoon that attic is dramatically hotter than the outdoor air, and considerably hotter than the 55°F air moving through the duct.

Two things happen when that duct leaks. Air you have already paid to cool escapes into the attic and never reaches a room. And on the return side, the system pulls superheated attic air into the return, so the air handler is trying to cool air that arrives hotter than the air in the house. The second is worse than the first, and it is common in older return configurations.

The visible result is a house that cannot hold setpoint on hot afternoons, a system that runs almost continuously, and rooms at the ends of long duct runs that are simply never comfortable. Homeowners usually assume the equipment is undersized. Frequently it is not.

The other consequence is humidity. A system pulling in unconditioned attic air is also pulling in that air’s moisture. In a metro averaging around 75% relative humidity, that shows up as a house that feels sticky even when the thermostat reads 74°F.

Worth knowing before you call

  • Which rooms are uncomfortable, and whether it is worse upstairs
  • Whether the problem is year round or only on very hot days
  • Roughly when the house was built, and whether ductwork has ever been replaced
  • Whether you have noticed dust returning quickly after cleaning
Call (855) 758-5353

24/7 emergency HVAC service. Office monday - saturday, 9:00am - 6:00pm.

What the work involves

Duct services

Leak testing and diagnosis

Measuring rather than guessing. Static pressure readings, airflow at the registers and a look at how the system was actually put together.

Sealing

Mastic and mechanical fastening at plenums, boots, branch takeoffs and joints, which is where the majority of leakage lives.

Resizing and redesign

Correcting trunk and branch sizes, adding return capacity, and fixing runs that were too long or too restricted from the start.

Replacement

New duct where the existing material is deteriorated, crushed, disconnected or so undersized that sealing it achieves nothing.

Rerouting for construction

Moving runs so a ceiling can be raised, a wall removed or a room added. This is where the construction side of the business does the heavy lifting.

Return air correction

Undersized returns are the single most common design fault in older houses here, and one of the most rewarding to fix.

The part nobody looks at

Return air is usually the real bottleneck

Almost every conversation about airflow focuses on the supply side, on which vents blow and how hard. The return side gets ignored, and it is where a large share of comfort problems actually originate.

A system can only push out as much air as it can pull in. If the return path is undersized, and in a great many houses built before returns were taken seriously it is, the blower is fighting a restriction on every cycle. That produces low airflow across the whole house, a coil running colder than it should, higher static pressure, more strain on the blower motor, and a persistent tendency toward frozen coils.

Two patterns show up repeatedly in this area. The first is a single central return sized for a much smaller system, usually because the equipment was upgraded at some point and the return never was. The second is bedrooms with supply vents but no return path at all, where closing the door effectively seals the room off. The room then pressurises, airflow into it drops, and it becomes the room that is always warm.

Both are fixable, and neither requires new equipment. Adding return capacity or cutting properly sized transfer paths often does more for comfort than anything that can be bought at the condenser.

Local housing stock

What we find in different neighbourhoods

Mid-century southwest Houston

Sharpstown was dedicated in 1955 and Meyerland was developed from 1955 onward, so the housing stock in that band of the city is now seventy years old. Duct systems there have frequently been replaced once, sometimes badly, and returns were sized for equipment that has since been upgraded twice. In Westbury the return side is the usual constraint.

Late-seventies to nineties Fort Bend

First Colony began in 1977 and Greatwood and New Territory came at the end of the eighties. Two-storey houses with attic air handlers dominate, and the usual finding is long flexible runs to upstairs rooms with sharp bends and sag between supports.

Newer master-planned areas

Telfair, Riverstone and Sienna are far newer and the duct is generally in better condition. Problems there tend to be design rather than deterioration: a room over a garage, a bonus room, or a two-storey volume that one thermostat cannot balance.

More on the areas we cover

Reviews

What customers say

Every published review is five stars, on Google and on Yelp. These are screenshots of the live profiles.

Read all 12 reviews

Why people call us

Why homeowners here choose Haswani

Three things that are checkable rather than assertable. Each one is either a number you can verify or something the company can actually do.

12 Published reviews, every one five stars

The reviews are screenshots, not retyped quotes

All 12 reviews on this site are shown as screenshots of the live Google and Yelp profiles, ten on Google and two on Yelp. A quote retyped into a web page is indistinguishable from one a marketer invented; a screenshot carries the platform’s own chrome, the reviewer’s name and the date. No average rating is claimed anywhere, because 12 screenshots prove these reviews exist without proving they are the complete set.

4 Trades inside one company

A duct that has to move does not become somebody else’s job

Haswani runs HVAC alongside construction, electrical and plumbing. A large share of comfort complaints are building problems rather than equipment failures: a return opening undersized when the house was framed, a duct run that has to be rerouted, a circuit that will not carry the new equipment. Most HVAC companies stop where the building begins and hand that off. Here it stays with the same company.

24/7 Emergency HVAC service, from a Stafford office

Somebody answers at two in the morning

Emergency HVAC service runs around the clock. Cooling failures are not spread evenly across the year: they cluster on the hottest afternoons, in a city averaging 102 days at or above 90°F. Office hours are monday - saturday, 9:00am - 6:00pm, and the emergency line is not bound by them. The office is on Murphy Road in Stafford, which puts the core service area within about fifteen minutes.

The longer version, including what this company is not

Ductwork questions

How do I know if my ducts are leaking?
The usual signs are rooms that never reach setpoint, a system that runs far longer than it should, dust that reappears immediately after cleaning, and summer electricity bills that climb without a change in habits. Leakage can be measured properly with a duct test rather than guessed at, and that is worth doing before spending money on a fix.
Is it better to seal ducts or replace them?
Sealing is right when the duct is intact, correctly sized and simply leaking at connections. Replacement is right when the duct is undersized for the system, physically deteriorated, crushed, or routed so badly that sealing it just makes an inadequate system airtight. The distinction is about condition and sizing, not age alone.
What does duct replacement cost?
National pricing data generally puts full duct replacement in the region of $15 to $30 per linear foot including removal, new duct and sealing, which for a typical single-family house often lands somewhere between about $3,000 and $6,000. Partial work costs proportionally less. The variables are accessibility, house size, how much has to be redesigned rather than replaced like for like, and attic conditions.
Do I need my ducts cleaned?
Duct cleaning and duct sealing are different things and get confused constantly. Cleaning removes accumulated debris and can be worthwhile after construction work, after a rodent problem or where there is visible contamination. It does not fix leaks, does not improve undersized duct and will not solve a room that has never cooled properly.

If particular rooms have never been comfortable, describing which ones and when narrows this down quickly.

Call (855) 758-5353

Rooms that never cool, whatever the thermostat says

That pattern usually points at distribution rather than equipment. Worth a conversation before anyone talks about a new system.

Duct or airflow problem? 24/7 emergency service · Stafford, TX
(855) 758-5353
(855) 758-5353